      Jeff Henderson
      Participant

      When the left elevator is positioned to neutral, the right elevator commands a slight nose up. This seems to be causing a small rolling moment.

      What’s the fix?

      Pics attached.

      Attachments:
      You must be logged in to view attached files.
    • #10560
      Roscoe Rosché
      Keymaster

      First try loosening the two attaching bolts (one per side) then hold the elevator at neutral and then re tighten. If that does not do it, then they have to be drilled out (only one) and that should do it.

    • #10561
      Jeff Henderson
      Participant

      Thank you.